GBS Prüfpuls rev3 pulse generator for long-term insulation testing up to 6 nFGBS Elektronik
rev3 Isolationstests bis 6nF
GBS Prüfpuls rev3 pulse generator for long-term insulation testing up to 6 nF
GBS Elektronik
rev3 Isolationstests bis 6nF
VB plus PDV
3.781 €
Stanje
Polovno
Lokacija
Borken 

Osnovni podaci
Cena i lokacija
VB plus PDV
3.781 €
- Lokacija:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Pozvati
Detalji ponude
- ID oglasa:
- A17569468
- Referentni broj:
- 21007
- Ažuriranje:
- последњи пут дана 21.10.2026
Opis
GBS Prüfpuls rev3 Pulse generator for long-term insulation tests
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Converter for high-voltage test transformer
Dwjdpfx Aou Egz Rjfxod
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
More items - new and used - can be found in our shop!
International shipping costs on request!
Oglas je automatski preveden. Moguće su greške u prevodu.
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Converter for high-voltage test transformer
Dwjdpfx Aou Egz Rjfxod
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
More items - new and used - can be found in our shop!
International shipping costs on request!
Oglas je automatski preveden. Moguće su greške u prevodu.
Dobavljač
Napomena: Besplatno se registrujte ili prijavite, da biste pristupili svim informacijama.
Registrovan od: 2008
534 Oglasi online
Pošalji upit
Telefon & Faks
+49 2862 ... oglasi
Ovi oglasi bi vas takođe mogli zanimati.
Uspešno
Vaša poruka je poslana.
Mali oglas
Wiefelstede
1.395 km
Klupa vise 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Vaš oglas je uspešno izbrisan
Došlo je do greške.